Skip to content

🔥O Range Smoke Control Panel - FSM Awards Shortlist: Fire Innovation of the Year!Discover More →

Single Zone Smoke Control Panels | O Range

O Range Smoke Control ideal for Single-Zone, Golden Thread Compliant, Protects The engineer and the residents. Smart : Secure : Verified: Connected. Fire Innovation of the Year Award-Shortlisted 2026

System Overview

The Intelligence at the Centre

prEN 12101-9aligned
Manufacturedin the UK
Next-Daydelivery
FSM Awards 2026: Fire Innovation of the Year Shortlisted

The O Range is an addressable smoke control panel for commercial and residential buildings, built around the Golden Thread set out by the Building Safety Act. Every configuration change is made by an authenticated engineer and recorded in a digital audit trail, so the system’s setup, commissioning and maintenance history stay attributable and traceable across the building’s whole life. It is shortlisted for Fire Innovation of the Year at the 2026 FSM Awards.

Two protections set it apart from older panels. First, configuration is locked behind engineer two-factor authentication, so the way the system is set up cannot be changed without authorised access, and there are no dip switches to quietly alter. Second, the firefighter override switches stay inactive in normal conditions and only become live during a smoke event, so residents and the public cannot operate the smoke system when there is no fire.

As the intelligence at the centre of the system, the panel takes signals from the fire alarm, manages cause and effect sequences, powers the actuators and extract fans, and provides firefighter override. It scales from a single-zone stairwell AOV to multi-zone commercial buildings. Vent Trade supplies the O Range and 400 Series, manufactured in the UK to prEN 12101-9 and held in stock for next-day delivery.

FSM Awards 2026: Fire Innovation of the Year Shortlisted
Smoke Control
Ventec O Range 7 addressable smoke ventilation control panel
VentecO Range 7 Smoke Control Panel

Certified smoke control panel for single stairwell to 60-zone networked systems. 24V 7A output with 72-hour battery backup. EN 12101-10 compliant.

  • Golden Thread ready
  • Zonal lockout
  • 1 to 60 zones
  • Built-in anti-trap protection
  • Secure configuration
Download Datasheet (PDF)

O Range Accessories

Smoke Accessories
O Range CSP visual status panel for smoke ventilation systems
O RangeCSP

Visual status panel for O Range smoke control. Fire, Fault and Healthy LEDs at a glance. Brushed steel finish, standard pattress box. EN 12101-10 compliant.

  • O Range compatible
  • Networkable
  • Fire / Fault / Healthy
Smoke Accessories
O Range firefighter override switch for smoke ventilation
O RangeFirefighter Switch

Manual override for smoke ventilation systems. Open or close smoke vents directly from stairwells and lobbies. Surface or flush mount. O Range compatible.

  • O Range compatible
  • prEN 12101-9
  • 1 zone control
  • Smoke + enviro
Smoke Accessories
O Range Connect Tool for on-site panel configuration and diagnostics
O RangeConnect Tool

Hardware commissioning tool for on-site O Range panel configuration, testing, and diagnostics. O Range Connect Tool connects to the O Range to allow configuration and monitoring of the software.

  • O Range compatible
  • 1 to 60 zones
  • Engineer 2FA
  • Golden Thread
Smoke Accessories
O Range optical smoke detector with relay base
O RangeSmoke Detector

Photoelectric smoke detector for O Range systems. 9–33Vdc operating range with relay base option. Ceiling or wall mount. Plug-and-play installation.

  • O Range compatible
  • 9-33Vdc range
  • Photoelectric

Specifier Guidance

What to Consider When Specifying

The right panel for a project depends on four key factors:

  • 1 The number of smoke control zones and whether single or multi-zone control is required
  • 2 The type of actuators and fans being controlled, including voltage and power requirements
  • 3 The fire alarm interface required: volt-free contact, protocol-based, or standalone detection
  • 4 Whether firefighter override switches are integrated into the panel or remote-mounted

Our technical team can confirm panel selection and provide cause and effect programming support during commissioning.

Technical Support

Talk to Our Panel Experts

Call our technical team for panel selection, cause and effect programming support, or to discuss system design. We support contractors from specification through to commissioning.

Panel selection & zone planning
Cause & effect programming support
Golden Thread compliance guidance
Commissioning engineer verification

Frequently Asked Questions

What is a single zone smoke control panel?

A single zone smoke control panel controls one smoke ventilation zone, most often the AOV system serving a single stairwell or lobby. It takes the fire signal for that zone, drives the actuators that open the vents or louvres, and provides firefighter override along with fault and status indication.

In the UK, the control panel is built to prEN 12101-9 and its power supply to BS EN 12101-10, and the firefighter override switch is built to align with prEN 12101-9. Panels include battery backup so the system keeps operating during a mains power failure.

Can the O Range panel run a single zone system?

Yes. The O Range 7 is configurable from a single zone up to 60 zones, so the same panel covers a single stairwell AOV as well as larger networked systems. For a single zone system the panel is set for one zone, with a firefighter override switch at the point of entry and the smoke detection and actuators serving that stair.

Because the configuration is held in software and locked behind engineer two-factor authentication, the commissioned setup stays attributable and traceable for the Golden Thread.