Visual status panel for O Range smoke control. Fire, Fault and Healthy LEDs at a glance. Brushed steel finish, standard pattress box. EN 12101-10 compliant.
- O Range compatible
- Networkable
- Fire / Fault / Healthy

Photoelectric sensing technology with wide 9-33Vdc operating voltage ensures reliable smoke detection across varying installation conditions and power supply setups.
Supplied complete with relay base for immediate installation. Up to 4 detectors per chain for comprehensive zone coverage from a single panel output.
Pulsing LED in quiescent state confirms the detector is operational. Red alarm indicator provides immediate visual identification of smoke events.
Well-proven photoelectric sensing technology for reliable point-type smoke detection in fire detection and alarm systems.
9-33Vdc operating range provides flexibility for different installation configurations and power supply setups.
Pulsing LED within the housing during quiescent state. External indicator LED turns red when in alarm for clear visual identification.
Complete with relay base for straightforward installation. OSD must be installed on a relay base to function as intended.
Up to 4 detectors per chain connection, allowing multiple detection points across a zone from a single O Range panel output.
Designed for use with the O Range smoke control panel system for smoke detection when no building fire alarm is present.
100mm diameter x 50mm height. Ceiling mounted with relay base for optimal smoke detection coverage.
4 core + earth cable connection. Refer to the O Range Installation Guide for detailed wiring instructions.
To restore to quiescent condition, expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.
O Range OSD Smoke Head and relay base: CXSM-ORA-SDET-0001
9-33Vdc operating range provides flexibility for different installation configurations and power supply setups across varied sites.
Up to 4 detectors per chain from a single O Range panel output, allowing multiple detection points across a zone.
Pulsing LED confirms operational status in quiescent state, with red alarm indicator for immediate visual identification of smoke events.
Designed and tested for use with the O Range smoke control system. Provides smoke detection when no building fire alarm is present.
Smoke ventilation systems require regular testing and record-keeping by authorised, competent persons. Servicing by accredited and certified smoke vent engineers only.
We have a team of ventilation specialists on hand to help guide you towards selecting and customising your system.